346     Centrifugal Pumps: Design and Application











































        Figure 16-5. Axial thrust on single-suction closed impellers with balance holes.




        Closed Impeller with front ring and back balancing ribs. Where it is
        not desirable to design the impeller with a back ring, axial thrust can be
        balanced by designing integrally cast ribs on the back of the impeller
        shroud. A gap between rib and cover of 0.015 in. maximum, permits the
        liquid to rotate at approximately full impeller angular velocity, thus re-
        ducing the pressure on the impeller back shroud over the area of the rib.
        This method of balance is not very accurate or positive. If the gap is in-
        creased, the pressure acting on the back shroud increases, resulting in
        higher axial loads. Experience has shown that this type of impeller is less
        efficient than one with a back ring. Axial thrust can be estimated as
        shown in Figure 16-7.