Page 120 - Centrifugal Pumps Design and Application
P. 120

NPSH     101










































                             Figure 8-19. Estimating K 2.


        Example

            Ignoring internal leakage back to the impeller, calculate NPSHR
          cavitation free for the pump now described.

          • Capacity—1,800 GPM
          • Product—Water
          • Temperature—70° F
          • Speed—8,100 RPM
          • Impeller eye area—17.2 sq in.
          • Eye diameter—5 in.
          • Inlet blade angle—15°
          • Suction area at A-B—24 sq in.
   115   116   117   118   119   120   121   122   123   124   125