48    Centrifugal Pumps: Design and Application

           Step 3

            Establish next size pump by multiplying each base line BEP by
          • GPM x 1,75
          • Head x 1,45


            Example: Smallest pump on chart has BEP of 86 GPM and 150-ft
          head. Thus, BEP for next size pump = 86 x 1.75 = 150 GPM and
           150 x 1.45 = 220 ft. Repeat this step for each base line BEP. As can
          be seen from the chart, the head of 220 ft now requires a 9-in. impeller,


          Step 4

            For all additional pump BEP's multiply preceding pump flow by
          1.75 and head by 1.45.

          The constants 1.75 and 1.45 are recommended for a well-planned per-
        formance chart following a number of constant specific speed lines.
        There are no gaps between pumps, each performance block can be cov-
        ered by normal impeller trim, and there are no overlaps. The chart is also
        helpful to the designer. In this example, only six small pumps have to be