Page 255 - Chemical process engineering design and economics
P. 255

236                                                      Chapter 5





                                                             ISOPSI,3j600RPM
                                                             (50PSI.I300RPM
                                                             600P$I,3*OOWM
                            -HALF-LOW  STEAM                 600PSI, 1.800RPH
                            -  RATE  FACTOR                  GEARED TURBINE
                                                                SEAR toss)
                                                             (ma.
                            -ATM.  BACK  PRESS.
                                                             150PSt,3,600RPtl
                                                             300PSI.3J600RM
                I                                            150PSI, 1.BOORPIII
                                                             300PSI, 1.800RPM
                                                             600PSLI.BOOWM




                         20   30  4050607080100   ZOO  300400500

                                        Brake Horsepower

            Figure  5.19  Isentropic  efficiencies  for  single-stage  noncondensing  tur-
            bines -  dry saturated steam.  From Ref. 31 with permission.







                         1.0


                         0.9


                         0.8

                         0.7

                         0.6  II
                                      100         200        300
                                      Initial Superheat, °F

            Figure  5.20  Efficiency  correction  factors  for single-stage  turbines  -  su-
            perheated steam.  From Ref. 31 with permission.





         Copyright © 2003 by Taylor & Francis Group LLC
   250   251   252   253   254   255   256   257   258   259   260