2.70 CHAPTER TWO
Outside corners or turns receive an additional strip of material usually 1 ft wide for
additional reinforcement (Fig. 2.90). Chalk lines should be used to keep vertical applica-
tions straight and to prevent fish mouthing of materials. All end laps, protrusions, and ter-
minations should be sealed with the clay mastic, as shown in Figs. 2.91 and 2.92. Proper
termination methods are shown in detail in Figs. 2.93 and 2.94.
FIGURE 2.90 Clay system applied to lagging detailing. Note reinforcement at corner. (Courtesy of TC