Page 326 - Construction Waterproofing Handbook
P. 326
6.26 CHAPTER SIX
FIGURE 6.25 Premanufactured vertical metal expansion joint. (Courtesy of the C/S Group)
FIGURE 6.26 Premanufactured vertical ribbed expansion joint. (Courtesy of the C/S Group)
Obviously, the system cannot be field-adapted for any conditions, with the possible
exception of shortening by field cuts. This requires that any termination or transitions be
covered by using premanufactured pieces provided by the manufacturer. A typical floor-
to-wall transition metal joint is shown in Fig. 6.32.
Below-grade expansion systems
Various treatments are used for below-grade expansion joints. As discussed in Chap. 2, these
joints typically are not subject to thermal movement, but only to movement from structural