Page 442 - Construction Waterproofing Handbook
P. 442
10.44 CHAPTER TEN
FIGURE 10.47 Lack of transitioning and termination detailing in original
construction will certainly lead to failure and leakage. (Courtesy of Coastal
Construction Products)
● Concrete deck installing
● Sheet metaling
● Electrical
● Curtain or window wall contracting
Among the related envelope components involved within a typical roofing envelope are
● Roof drains
● Lightning rods
● Balustrades
● Mechanical equipment
● Electrical equipment
● Signs
● Copings
● Skylights
● Parapets
● Penthouse walls
It is important that each of these envelope components be completely waterproof itself
to ensure a roofing envelope’s effectiveness. Terminations and transitions necessary to