Page 491 - Construction Waterproofing Handbook
P. 491

LEAK INVESTIGATION AND DETECTION  13.7


                             ENVELOPE AREA        North       South       East        West
                                                  Elevation   Elevation   Elevation   Elevation

                           Walls:
                           Substrate & Backing  (e.g.
                           EIFS, stone,  masonry
                           Flashings

                           Divertor  systems
                          Transitions between
                           substrates
                           Waterproofing  applications
                           (clear repellents, coatings)
                           Directional  changes
                           Horizontal abutments

                           Materials delaminating
                           Louvers/ AC unit/other
                          penetrations
                           Deteriorated
                           expansion/control joints
                           Cracked mortar joints

                           Efflorescence
                           Clogged weep  holes

                          Deteriorated mortar joints
                           Spalling of stone,  concrete, or
                          masonry
                           Structural cracks in  substrate
                           Rusting of shelf  angles,
                           anchors
                           Broken window or curtain
                           wall  panes



                         FIGURE 13.2 Envelope inspection form.