Page 53 - Defrosting for Air Source Heat Pump
P. 53
Previous related work: A review 43
[90] Qu ML, Xia L, Deng SM, Jiang YQ. Improved indoor thermal comfort during defrost with
a novel reverse-cycle defrosting method for air source heat pumps. Build Environ
2010;45:2354–61.
[91] Mao N, Deng SM. Application of TOPSIS method in evaluating the effects of supply vane
angle of a task/ambient air conditioning system on energy utilization and thermal comfort.
Appl Energy 2016;180:536–45.
[92] Mao N, Deng SM, Pan DM, Chen SJ. Experimental and numerical study on air flow and
moisture transport in sleeping environments with a task/ambient air conditioning (TAC)
system. Energy Build 2016;133:596–604.
[93] Mao N, Pan DM, Deng SM. Computational fluid dynamics analysis of convective heat
transfer coefficients for a sleeping human body. Appl Therm Eng 2017;117:385–96.
[94] Niu FX, Ni L, Yao Y, Yu YB, Li HR. Performance and thermal charging/discharging fea-
tures of a phase change material assisted heat pump system in heating mode. Appl Therm
Eng 2013;58(1):536–41.
[95] Chen C, Ouyang J, Wang XL, Liu M. New method of heat compensation for defrosting of
air source heat pump system in winter. J Refrig 2006;27:37–40.
[96] Qu ML, Xia L, Deng SM, Jiang YQ. A study of the reverse cycle defrosting performance
on a multi-circuit outdoor coil unit in an air source heat pump-Part I: experiments. Appl
Energy 2012;91:122–9.
[97] Hu WJ, Jiang YQ, Qu ML, Yao Y, Deng SM. An experimental study on the operating
performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps.
Appl Therm Eng 2011;31:363–9.
[98] Dong JK, Li S, Yao Y, Jiang YQ, Tian Y, Tian H. Defrosting performances of a multi-split
air source heat pump with phase change thermal storage. Int J Refrig 2015;55:49–59.
[99] Qu ML, Li TR, Deng SM, Fan YN, Li Z. Improving defrosting performance of cascade air
source heat pump using thermal energy storage based reverse cycle defrosting method.
Appl Therm Eng 2017;121:728–36.
[100] Zhang L, Dong JK, Jiang YQ, Yao Y. A novel defrosting method using heat energy dis-
sipated by the compressor of an air source heat pump. Appl Energy 2014;133:101–11.
[101] Wu JH, Yang ZG, Wu QH, Zhu YJ. Transient behavior and dynamic performance of cas-
cade heat pump water heater with thermal storage system. Appl Energy 2012;91
(1):187–96.
[102] Dong JK, Jiang YQ, Yao Y, Zhang XD. Operating performance of novel reverse-cycle
defrosting method based on thermal energy storage for air source heat pump. J Cent
South Univ Technol 2011;18:2163–9.
[103] Aganda AA, Coney JER, Farrant PE, Sheppard CGW, Wongwuttanasatian T.
A comparison of the predicted and experimental heat transfer performance of a finned
tube evaporator. Appl Therm Eng 2000;20:499–513.
[104] Aganda AA, Coney JER, Sheppard CGW. Airflow maldistribution and the performance
of a packaged air conditioning unit evaporator. Appl Therm Eng 2000;20:515–28.
[105] Kim JH, Braun JE, Groll EA. A hybrid method for refrigerant flow balancing in multi-
circuit evaporators: upstream versus downstream flow control. Int J Refrig
2009;32:1271–82.
[106] Kim JH, Braun JE, Groll EA. Evaluation of a hybrid method for refrigerant flow
balancing in multi-circuit evaporators. Int J Refrig 2009;32:1283–92.
[107] Alebrahim AM, Sherif SA. Electrical defrosting analysis of a finned tube evaporator coil
using the enthalpy method. Proc Inst Mech Eng C: J Mech Eng Sci 2002;216:655–73.
[108] Liu ZQ, Tang GF, Zhao FY. Dynamic simulation of air-source heat pump during hot-gas
defrost. Appl Therm Eng 2003;23:675–85.