Page 611 - Dust Explosions in the Process Industries
P. 611

578  Dust Explosions in the Process industries

            Greiner, H. (2001, September) “IP Degrees of  Protection.” Danfoss publication SD  101 E, BAU
              5003784. Esslingen, Germany: Danfoss Bauer GmbH.
            Greiner, H. (2002, March) “Explosionsschutzbei Getriebemotoren, Teil 111:Staub-explosionsschutz.”
              Danfoss publication SD 302, BAU 5004071.Esslingen, Gemany: Danfoss Bauer GmbH, pp. 18/1-LiIW3.
            Harper, D. J., K. E. Plain, and J. S. Wilton. (1997) “Use of Intrinsically Safe Circuits and Enclosures
              to Control the Ignition Risk from Equipment in Powder Handling Plant.” In Hazards XZIZ. ICHEME
              Symposium Series No. 141. Rugby, UK: Institution of Chemical Engineers, pp. 463480.
            IEC. (1992, November) “Hazard Classificationof Combustible Dusts.” Doc. SC31H(Sec)l9. Geneva:
              International Electrotechnical Commission.
            IEC. (1994a) “Method for Determining Minimum Ignition Energy of Dust/Air Mixtures.” IEC inter-
              national standard 1241-2-3. Geneva: International Electrotechnical Commission.
            IEC. (1994b) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 2: Test Meth-
              ods. Section 1: Methods for Determining the Minimum Ignition Temperatures of Dust.” Geneva:
              Central Office of IEC.
            IEC. (1999a) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 1-1. Electrical
              Apparatus  Protected  by  Enclosures  and  Surface  Temperature  Limitation-Specification   of
              Apparatus.” IEC final draft international standard 61241-1-1, 1999-02-12. Geneva: International
              Electrotechnical Commission.
            IEC. (1999b) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 1-2. Electrical
              Apparatus Protected by Enclosures and SurfaceTemperatureLimitation-Selection,   Installation and
              Maintenance.”  IEC final draft international  standard 61241-1-2, Second ed.  1999-06. Geneva:
              International Electrotechnical Commission.
            IEC. (1999~)“Electrical Apparatus for Explosive Gas Atmospheres. Part  11. Intrinsic Safety ‘i’.”
              International standard IEC 60079-11. Geneva: International Electrotechnical Commission.
            IEC. (2001a) Draft SPS for discussion at the meeting of TC 31 in Seoul, IEC document 31/376/LNF.
              2001-05-04, p. 3 (SC 31H). Geneva: International Electrotechnical Commission.
            IEC. (2001b, March) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 4: Type
              of  Protection  ‘pD’.”  IEC international standard 61241-4. Geneva: International Electrotechnical
              Commission, Central Office.
            IEC. (2001c, February) “Degrees of Protection Provided by Enclosures (IP Code),” 2nd ed. IEC inter-
              national standard 60529. Geneva: International Electrotechnical Commission, Central Office.
            IEC. (2001d, February) “Electrical Apparatus for Explosive Gas Atmospheres. Part 2. Pressurised
              Enclosures ‘p’,”4th ed. IEC international standard 60079-2. Geneva: International Electrotechnical
              Commission, Central Office.
            IEC. (2002a) Proposed change to the scope of TC 3 1, IEC document 31/405/Q, 2002-02-01. Geneva:
              International Electrotechnical Commission.
            IEC. (2002b) “ElectricalApparatus for Use in the Presence of CombustibleDust. Part 10. Classification
              of Areas Where Combustible Dusts Are or May Be Present.” Draft IEC international  standard
              61421-10, 2002-04-26. Geneva: International Electrotechnical Commission.
            IEC. (2002~)“Electrical Apparatus for Use in the Presence of Combustible Dust. Part 0. General
              Requirements.”  IEC draft international  standard  61421-0, 2002-04-26.  Geneva: International
              Electrotechnical Commission.
            IEC. (2002d) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 1. Protection
              by Enclosure ‘tD’.”IEC draft international standard 61421-1, 2002-04-26. Geneva: International
              Electrotechnical Commission.
            IEC. (2002e) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 14. Selection
              and Installation.’’ IEC draft international standard 61421-14, 2002-04-26. Geneva: International
              Electrotechnical Commission.
            IEC. (2002f) “Electrical Apparatus for Use in the Presence of Combustible Dust. Part 18. Protection
              by  Encapsulatione  ‘mD’.” IEC  draft  international  standard  61421-18,  2002-09-6.  Geneva:
              International Electrotechnical Commission.
   606   607   608   609   610   611   612   613   614   615   616