Page 90 - Electrical Engineering Dictionary
P. 90

n
                              of (a + b) . These coefficients are equal to  i.e., the product of the polyphase transfer
                                                                     function of the analysis and synthesis filters

                                         n        n!
                                            =          ,             is a pure delay. In general, the analysis and
                                         k     k!(n − k)!
                                                                     synthesis filters are different, as opposed to
                              where n is the order of the polynomial and k  the situation for an orthogonal filter bank.
                              is the index of the coefficient. The kth coef-
                                                        k n−k
                              ficient is multiplied by the term a b  .  biorthogonal wavelet  a generalization of
                                                                     orthogonal wavelet bases, where two dual ba-
                              binomial distribution  the binomial dis-  sis functions span two sets of scaling spaces,
                              tribution is the distribution of a random vari-  V j and V j , and two sets of wavelet spaces,
                                                                           ˆ
                              able Y that is the sum of n random variables  W j and W j , with each scaling space orthog-
                                                                            ˆ
                              that are Bernoulli distributed.                                         ˆ
                                                                     onal to the dual wavelet space, i.e., V j ⊥ W j
                                                                         ˆ
                                     Y = X 1 + X 2 + ··· + X n .     and V j ⊥ W j . See also biorthogonal filter
                                                                     bank.
                              The probability mass function of such a Y is

                                            n    k      n−k          BIOS    See basic input–output system.
                                   p Y (k) =    p (1 − p)  ,
                                             k
                                                                     bipolar    (1) a type of transistor that
                              where p is the parameter of the Bernoulli dis-
                                                                     uses both polarities of carriers (electrons and
                              tribution of any X i .
                                                                     holes) in its operation as a junction transistor.
                              bioanalytical sensor   a special case    (2) a type of data encoding that uses both
                              of a chemical sensor for determining the  positive and negative voltage excursions.
                              amount of a biochemical substance. This
                              type of sensor usually makes use of one  bipolar device  See bipolar.
                              of the following types of biochemical reac-
                              tions: enzyme-substrate, antigen-antibody,  bipolar junction transistor (BJT)  a
                              or ligand-receptor.                    three-terminal nonlinear device composed of
                                                                     two bipolar junctions (collector-base, base-
                              bioluminescence  See luminescence.     emitter) in close proximity. In normal oper-
                                                                     ation, the voltage between base and emitter
                              biomass    General term used for wood,  terminals is used to control the emitter cur-
                              wood wastes, sewage, cultivated herbaceous  rent. The collector current either equals this
                              and other energy crops, and animal wastes.  (with BC junction in reverse bias), or goes
                                                                     into saturation (the BC junction goes into for-
                              biomedical sensor  a device for interfac-
                                                                     ward bias). Used for medium power (700 A)
                              ing an instrumentation system with a biolog-
                                                                     and medium speed (10 kHz) applications.
                              ical system such as biological specimen or an
                                                                       In power electronics applications, BJTs
                              entire organism. The device serves the func-
                                                                     are typically operated as switches, in either
                              tion of detecting and measuring in a quanti-
                                                                     their fully on or off states, to minimize losses.
                              tative fashion a physiological property of the
                                                                     The base current flowing into the middle of
                              biological system.
                                                                     the device controls the on–off state, where
                                                                     continuous base current is required to be in
                              biometric verifier  device that helps au-
                                                                     the on state. A disadvantage is the low cur-
                              thenticate by measuring human characteris-
                                                                     rent gain.
                              tics.
                                                                       The base current is generally much
                              biorthogonal filter bank  a filter bank that  smaller than collector and emitter currents,
                              satisfies the perfect reconstruction condition,  but not negligible as in MOSFETs.
                              c 
2000 by CRC Press LLC
   85   86   87   88   89   90   91   92   93   94   95