Page 187 - Estimators Piping Man Hour Manual
P. 187

170    Section Four—MECHANICAL INSTRUMENTATION

                        LIQUID   LEVEL   GAUGE    GLASSES


                                     Reflex  Type


                                   MAN HOURS EACH



                      Visible
                      Length                   Man Hours Each
                      Inches             CS               316SS
                       6-3/4             4.40             4.84
                      10-1/4             5.06             5.56
                      12-5/8             6.38             7.01
                      19-3/4             6.93             7.62
                      26-3/4             6.98             7.67
                      33-3/4             7.59             8.34
                      45-1/2             8.25             9.07
                      55                 8.91             9.80
                      65-3/8            10.12             11.13
                      78-3/4            11.44             12.58
      Note: CS = carbon steel, SS = stainless steel
      Above rating 2,400 psi  @ 100° F to  550 psi  @ 600° F.
      Man hours are based on Penberthy RLC Series.
      Man hours include checking out of storage, calibrating if necessary, hauling to location and installing. Man hours do
      not include valve, piping, or any electrical installation. If liquid level gauge valves are required, use 2.0 man hours
      per pair.