Page 32 - Flexible Robotics in Medicine
P. 32

14   Chapter 1

            [11] M.S. Moses, R.J. Murphy, M.D. Kutzer, M. Armand, Modeling cable and guide channel interaction in a
                 high-strength cable-driven continuum manipulator, IEEE/ASME Trans. Mechatron. 20 (6) (2015)
                 2876 2889.
            [12] A. Bajo, R.E. Goldman, L. Wang, D. Fowler, N. Simaan, Integration and preliminary evaluation of an
                 insertable robotic effectors platform for single port access surgery, in: 2012 IEEE International
                 Conference on Robotics and Automation (ICRA), IEEE, May 2012, pp. 3381 3387.
            [13] H.T. Sen, N. Deshmukh, R. Goldman, P. Kazanzides, R.H. Taylor, E. Boctor, et al., Enabling
                 technologies for natural orifice transluminal endoscopic surgery (NOTES) using robotically guided
                 elasticity imaging, in: Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and
                 Modeling, vol. 8316, International Society for Optics and Photonics, February 2012, p. 83161Y.
            [14] S. Thakkar, M. Awad, K.C. Gurram, S. Tully, C. Wright, S. Sanan, et al., A novel, new robotic platform
                 for natural orifice distal pancreatectomy, Surg. Innov. 22 (3) (2015) 274 282.
            [15] Y.J. Kim, S. Cheng, S. Kim, K. Iagnemma, A stiffness-adjustable hyper-redundant manipulator using a
                 variable neutral-line mechanism for minimally invasive surgery, IEEE Trans. Robot. 30 (2) (2014)
                 382 395.
            [16] T. Kato, I. Okumura, S.E. Song, A.J. Golby, N. Hata, Tendon-driven continuum robot for endoscopic
                 surgery: preclinical development and validation of a tension propagation model, IEEE/ASME Trans.
                 Mechatron. 20 (5) (2015) 2252 2263.
            [17] A. Gao, H. Liu, Y. Zhou, Z. Yang, Z. Wang, H. Li, A cross-helical tendons actuated dexterous continuum
                 manipulator, in: 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS),
                 IEEE, September 2015, pp. 2012 2017.
            [18] B. Ouyang, Y. Liu, D. Sun, Design of a three-segment continuum robot for minimally invasive surgery,
                 Robot. Biomim. 3 (1) (2016) 2.
            [19] Z. Li, R. Du, Design and analysis of a bio-inspired wire-driven multi-section flexible robot, Int. J. Adv.
                 Robot. Syst. 10 (4) (2013) 209.
            [20] M. Ho, A. McMillan, J.M. Simard, R. Gullapalli, J.P. Desai, Towards a meso-scale SMA-actuated MRI-
                 compatible neurosurgical robot, IEEE Trans. Robot. 2011 (99) (2011) 1.
            [21] K.W. Kwok, V. Vitiello, G.Z. Yang, Control of articulated snake robot under dynamic active constraints,
                 in: International Conference on Medical Image Computing and Computer-Assisted Intervention, Springer,
                 Berlin, Heidelberg, September 2010, pp. 229 236.
            [22] K. Harada, D. Oetomo, E. Susilo, A. Menciassi, D. Daney, J.P. Merlet, et al., A reconfigurable
                 modular robotic endoluminal surgical system: vision and preliminary results, Robotica 28 (2) (2010)
                 171 183.
            [23] F.E. Cepolina, M. Zoppi, Design of multi-degrees-of-freedom dexterous modular arm instruments for
                 minimally invasive surgery, Proc. Inst. Mech. Eng. H J. Eng. Med. 226 (11) (2012) 827 837.
            [24] O.M. Omisore, S. Han, L. Ren, N. Zhang, K. Ivanov, A. Elazab, et al., Non-iterative geometric approach
                 for inverse kinematics of redundant lead-module in a radiosurgical snake-like robot, Biomed. Eng. Online
                 16 (1) (2017) 93.
            [25] J. Son, C.N. Cho, K.G. Kim, T.Y. Chang, H. Jung, S.C. Kim, et al., A novel semi-automatic snake robot
                 for natural orifice transluminal endoscopic surgery: preclinical tests in animal and human cadaver models
                 (with video), Surg. Endosc. 29 (6) (2015) 1643 1647.
            [26] B.L. Conrad, J. Jung, R.S. Penning, M.R. Zinn, Interleaved continuum-rigid manipulation: an augmented
                 approach for robotic minimally-invasive flexible catheter-based procedures, in: 2013 IEEE International
                 Conference on Robotics and Automation (ICRA), IEEE, May 2013, pp. 718 724.
            [27] B.L. Conrad, M.R. Zinn, Interleaved continuum-rigid manipulation approach: development and functional
                 evaluation of a clinical scale manipulator, in: 2014 IEEE/RSJ International Conference on Intelligent
                 Robots and Systems (IROS 2014), IEEE, September 2014, pp. 4290 4296.
            [28] H. Lee, K.G. Kim, J.H. Seo, D.K. Sohn, Natural orifice transluminal endoscopic surgery with a snake-
                 mechanism using a movable pulley, Int. J. Med. Robot. 13 (4) (2017) e1816.
            [29] X. Dong, M. Raffles, S.C. Guzman, D. Axinte, J. Kell, Design and analysis of a family of snake arm
                 robots connected by compliant joints, Mech. Mach. Theory 77 (2014) 73 91.
   27   28   29   30   31   32   33   34   35   36   37