Page 205 - Formulas and Calculations for Petroleum Engineering
P. 205

198 Formulas and calculations for petroleum engineering



              Formula(s)


                                                                     ! !  1
                                                              2
                                                        ð 1 øÞ     ø
                                                   Dt ¼        +
                                                          Dt      Dt
                                                            ma      f
              Reference: Bassiouni, Z., 1994, Theory, Measurement, and Interpretation of Well Logs. SPE Textbook Series Vol. 4.
              Chapter 3, Page: 56.


              3.50   Reservoir permeability
              Input(s)

                 q o :  Oil Flow Rate (bbl/d)
                 B o :  Oil Formation Volume Factor (bbl/STB)
                 m o :  Oil Viscosity (cP)
                 m:   Slope of Horner Plot (psi/cycle)
                 h:  Pay zone of Thickness (ft)

              Output(s)
                 k o :  Reservoir Permeability (mD)


              Formula(s)

                                                                       m o
                                                  k ¼ 162:6   qðÞ   B Þ
                                                                 ð
                                                              o
                                                   o
                                                                   o
                                                                      m   h
              Notes: Permeability Evaluated from Horner Plot (Semi-Log Plot).
              Reference: Lee, J., Rollins, J. B., & Spivey, J. P. (2003). Pressure Transient Testing (Vol. 9). Richardson, Texas: Society of
              Petroleum Engineers, Page: 104.
              3.51   Shut-in time for pressure build-up test (Dietz method)

              Input(s)
                 ø:  Porosity (fraction)
                                    2
                 A:   Drainage Area (ft )
                 C A :  Shape Factor (dimensionless)
                 m:  Viscosity (cP)
                 c t :  Total Compressibility (1/psi)
                 k:  Permeability (mD)

              Output(s)
                 t s :  Shut-in Time (h)


              Formula(s)

                                                           ø   m   c   A
                                                                  t
                                                     t ¼
                                                      s
                                                         0:0002637   C   k
                                                                    A
              Reference: Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 1,
              Page: 63.
   200   201   202   203   204   205   206   207   208   209   210