Be st Practice 3 .28          Compressor Best Practices


         Best
         Best
         Best Practice 3.28Practice 3.28Practice 3.28
         Re-rates e consider the drive system (transmission and  power limitations and in some cases, hydraulic coupling
         driver power limitations) and suction drum limitations to  slippage requiring rotor and coupling replacement.
         optimize reliability and production rates.           Failure to check suction drum for re-rate maximum flow conditions
           Confirm sufficient driver, coupling, gear (if applicable) power/torque  has resulted in:
         capability.                                          Fouling
           Confirm that the suction drum entrainment velocity limit is not    Liquid entrainment damage
         exceeded.                                            Suction drum demister deterioration
           Exceeding the entrainment velocity limit can result in compressor    Liquid carryover into the compressor
         fouling and/or suction drum demister deterioration and damage.
         Lessons Learned                                    Benchmarks
                                                            This best practice has been used in all re-rate projects performed by
         Failure to consider sufficient drive system capability has
                                                            FAI since the mid-1980s to ensure trouble free re-rate start-ups, and
         resulted in less than desired re-rate capacity, based on
                                                            compressor reliabilities exceeding 99.7%.






























































           228