Page 258 - Fundamentals of Magnetic Thermonuclear Reactor Design
P. 258

First Wall Components  Chapter | 7    239








































             FIGURE 7.9  Possible configurations including rotating cylinders.



               TABLE 7.7 Methods for Increasing Heat Loads, Which Divertor Targets Can
               Steadily Withstand
                                                      Largest permissible heat
                                                                      2
               Concept            Method              flow density (MW/m )
               Expansion of target   Separatrix repositioning
               area withstanding the   Target displacement
               heat flow
               Heat flows partial   Use of radiating target  2.5
               redistribution     Particle reflection
                                  Use of evaporating target  40.0
               Cooling mode       Enhancement of      Water (40.0) Helium (10.0)
               optimisation       coolant’s heat absorbing   Liquid metal pumped through
                                  capacity Heat exchange   the channel (5.0) Freely
                                  intensification     flowing liquid metal (30.0)
   253   254   255   256   257   258   259   260   261   262   263