Application of Gas Wettability CHAPTER 6                  215





                                                      Foaming agent
                                        Bubble




                                                       FGC-1










                                 Polarity end    Nonpolarity end
              FIGURE 6.12
              Diagram of FGC-1 micro-function mechanism.


                       6–8 meshes                  8–10 meshes









                        10–20 meshes              20–40 meshes












              FIGURE 6.13
              FGC-1 cutting carrying effect based on different mesh numbers.

              clusters. A few of the cuttings with grain diameter greater than 2.00 mm or less
              than 0.90 mm are carried by bubbles. However, most of the cuttings are depos-
              ited at the bottom of flasks. Bubbles also adhere on the surface.

              6.2.3   Evaluation of FGC-1 Cutting Carrying Effect
              in the Simulator
              A set of devices was independently designed to simulate and evaluate the
              effect of FGC-1 cutting carrying agent in greatly displaced wellbores, at