Page 252 - Handbook of Energy Engineering Calculations
P. 252

FIGURE 1  Reactor  plant  with  two-coolant  system  uses  Na  in  the
                     reactor circuit and transfers heat to the intermediate NaK circuit, which

                     acts as a buffer against making the steam circuit radioactive.



               Calculation Procedure:


               1. Determine the steam outlet and saturation temperature
               Figure  1  shows  that  NaK  enters  the  boiler  at  950°F  (510.0°C).  Draw  a
               horizontal line on the enthalpy-temperature (h-t) diagram (Fig. 2), indicating

               the  950°F  (510.0°C)  NaK  temperature  entering  the  boiler.  Also  draw  a
               horizontal line on the h-t diagram, Fig. 2, at 1000°F (537.8°C), indicating the
               Na temperature leaving the reactor.