494   Industrial Wastewater Treatment, Recycling, and Reuse




                                                             Vapors
                  Steam
                                                               Feed







                  Condensate




                  Concentrated
                  product

          Figure 13.2 Forced circulation evaporator.




          •  This type of evaporator can operate with minimal temperature differ-
             ences between the heating media and the boiling liquid, and therefore,
             it involves a greater number of effects.
          •  Scaling inside the tubes is less, leading to high operating time.
          •  Forced circulation evaporators can be installed vertically as well as hor-
             izontally, thereby saving space.


          Limitations
          •  Relatively high heat transfer area, leading to higher CAPEX.
          •  Higher recirculation rates, leading to higher power requirements and
             thus higher OPEX.



          13.3.1.3 Forced Falling Film Evaporator
          This design is a variation on the conventional falling film evaporator, and has
          additional benefits in terms of the following:
          •  It has all of the advantages of conventional falling film evaporation (see
             Figure 13.3).
          •  Proper wetting rate in the tubes is achieved by using spraying nozzles.
          •  It is less prone to fouling than its conventional counterparts.