98  Boilers

                 blown  through  and  checked  for  correct  reading.  When  the  steam
                 pressure is about 300 kPa (3 bar) below the  normal operating value  the
                 safety  valves should  be lifted  and  released  using the easing  gear.
                   Once  at  operating  pressure  the  boiler  may be  put  on  load  and  the
                 superheater  circulating  valves  closed.  All  other  vents,  drains  and
                 bypasses should then  be closed. The  water level in the  boiler should be
                 carefully  checked  and  the  automatic  water  regulating arrangements
                 observed  for correct operation.