Page 144 - Know and Understand Centrifugal Pumps
P. 144

The System Curve


       arrangement.  Any  three  pumps,  by  the  system  design,  indicate  that
       you’ll  be operating two pumps on one side of the system and one pump
       on the other side. The third pump will  not be able to open the check
       valve with two pumps keeping it closed. So in practice, you can operate
       any one pump, or any two pumps (with the aforementioned hints from
       the parallel operation section), or four pumps, but not three pumps.
       The curve, shown in Figure 8-3 1, is indicative of this operation.