Page 235 - Know and Understand Centrifugal Pumps
P. 235

Know and Understand Centrifugal Pumps





             This method requires a  source or w ater or steam for the quench.  The pumped liquid
             may contaminate the drainage.  If sc I, it should be discarded.



       The heat exchanger
         The  heat  exchanger  is  good  for  controlling  temperature  in  the  seal
         chamber  utilizing  the  same  pumped  product.  This  method  doesn’t
         dilute the product.
























         PUMP
        SUCllON
       Figure 14-19  The heat exchanger


       The double or dual mechanical seal
         The  dual  seal  is  good  to  control  the  environment  inside  the  seal
         without  diluting  the  pumped  product.  It  works  with  re-circulated
         barrier fluid. It establishes a barrier between the pumped fluid and the
         environment (Figure 14-20).

         You’ve  just  seen  six  different  concepts  to  control  the  environment
         inside  the  seal  chamber  and  mechanical  seal.  Some  methods  are
         economical.  Others  are  costly.  Some  have  secondary  side  effects  to
         contend with. Now let’s consider the 14 difficult sealing situations and
         apply the environmental controls to extend the running time of the seal
         and pump.
   230   231   232   233   234   235   236   237   238   239   240