Page 86 - Know and Understand Centrifugal Pumps
P. 86

Pump CI assi fica ti o n

                            HYDROCARBONS
                   MINIMUM CONTINUOUS FLOW AS % OF BEP FLOW
                         ON NON-TRIMMED IMPELLER.
                  USE 1/2 BEP FLOW FOR DOUBLE SUCTION IMPELLERS
       100


        200

        300

        400
        500
        600
        700
        800
        900
      1 .ooo



      2.000
      3.000
      4.000
      5.000
      6.000
      7.000
      8.000
      9.000
      10.000


     20.000

      30.000

                          WATER BASED LIQUIDS
          MINIMUM CONTINUOUS FLOWAS % OF BEP FLOW ON FULL SIZED IMPELLER.
                 FOR DOUBLE SUCTION IMPELLERS, USE 1/2 BEP FLOW
     Figure 6-15
                         ___   ~~~
       operate this pump at less than 42% of the REP. 42% of 600 gpm is 252
       gpm. The operator of this pump should not throttle a control valve and
       restrict  this pump at less than  252 gpm. If the operator throttles  this
       pump  to  240  gpm,  and  goes  to  lunch,  he’ll  probably  have  an
       emergency when he returns from his lunch break. Actually this failure
       would  be  an operation-induced  failure. If you’re  mistreating your car,
       you cannot blame the mechanic.
       In the  Second example,  the  line  terminates at  29%. This  means  DO
       NOT operate this pump at less than 29% of the BEP. 29% of 1200 gprn


                                                                  69
   81   82   83   84   85   86   87   88   89   90   91