2200  —  —  —  —  —  —  —  —  —  —  —  —  —  57.5  59.7  62.2  64.9  67.9  71.3  75.2  79.8  85.2  91.8



                             2000  —  —  —  —  —  —  —  —  —  —  —  51.0  52.8  54.9  57.1  59.6  62.4  65.5  69.1  73.2  78.0  83.8  90.9



                             1800  —  —  —  —  —  —  —  —  —  44.7  46.3  48.0  49.9  52.0  54.2  56.8  59.6  62.8  66.5  70.8  75.9  82.2  89.9


                             1600  —  —  —  —  —  —  —  38.7  40.1  41.5  43.0  44.7  46.6  48.7  51.0  53.5  56.4  59.7  63.5  68.0  73.5  80.2  88.7



                             1500  —  —  —  —  —  —  35.8  37.0  38.3  39.7  41.3  43.0  44.8  46.9  49.2  51.7  54.6  58.0  61.9  66.4  72.0  79.0  87.9


                         ( F)  1400  —  —  —  —  —  33.0  34.1  35.3  36.5  37.9  39.4  41.1  42.9  45.0  47.2  49.8  52.7  56.1  60.0  64.7  70.4  77.7  87.1
                      Air a  Temperature

                      Excess  1300  —  —  —  —  30.2  31.2  32.2  33.4  34.6  36.0  37.5  39.1  40.9  42.9  45.2  47.7  50.6  54.0  58.0  62.8  68.7  76.2  86.1  Co.

                      10%  Air                                                           capacity.
                      and  Combustion  1200  —  —  —  27.5  28.4  29.3  30.3  31.4  32.7  34.0  35.4  37.0  38.8  40.8  43.0  45.5  48.4  51.8  55.8  60.7  66.7  74.6  85.0  Manufacturing
                      Gas                                                                system
                      Natural  t 2 ,  1100  —  —  24.8  25.6  26.4  27.3  28.3  29.4  30.6  31.8  33.2  34.8  36.5  38.5  40.6  43.1  46.0  49.4  53.4  58.4  64.6  72.7  83.7  determining  American


                      with                                                               for  North
                      Air    1000  —  22.2  22.9  23.6  24.4  25.3  26.2  27.2  28.3  29.6  30.9  32.4  34.1  36.0  38.1  40.5  43.4  46.7  50.8  55.7  62.1  70.5  82.2  air—not  I,  Vol.
                      Preheated  900  19.6  20.2  20.9  21.5  22.3  23.1  24.0  24.9  26.0  27.1  28.4  29.9  31.5  33.3  35.3  37.7  40.5  43.8  47.8  52.8  59.3  68.0  80.4  Handbook,


                      of                                                                 preheated
                      Use    800  17.6  18.2  18.7  19.4  20.1  20.8  21.6  22.5  23.5  24.6  25.8  27.2  28.7  30.4  32.4  34.7  37.3  40.6  44.5  49.5  56.0  65.0  78.3  to
                      from                                                               change  Combustion

                      Resulting  700  15.5  16.0  16.6  17.1  17.8  18.5  19.2  20.2  20.9  21.9  23.0  24.3  25.7  27.3  29.2  31.3  33.9  37.0  40.8  45.7  52.3  61.5  75.6  proposed  a  from


                      (%)    600  13.4  13.8  14.3  14.8  15.3  16.0  16.6  17.4  18.2  19.1  20.1  21.2  22.5  24.0  25.7  27.7  30.1  33.0  36.7  41.4  47.9  57.3  72.2  evaluating  permission
                      Savings                                                            for  with


                      Fuel   ( F)                                                        are  figures  Reproduced

                      2  Furnace  Exit  Temperature
                      Table  t 3 ,  Gas  1000  1100  1200  1300  1400  1500  1600  1700  1800  1900  2000  2100  2200  2300  2400  2500  2600  2700  2800  2900  3000  3100  3200  a These  Source:



                                                                                                367
   373   374   375   376   377   378   379   380   381   382   383