Page 341 - Offshore Electrical Engineering Manual
P. 341
Additional Information DP system without redundancy. Manual position control system fitted with automatic heading control and with a freestand- ing position reference system. No redundancy required, but secure UPS units provided for critical systems, and auto- matic starting of standby generator. DP system with an independent joystick system back-up and a position reference back-up. DP system with an independe
Table 6.1.1 DP Class Notations: Comparison With DNV GL and ABS
DP(CM) DP(AM) DP(AA)
LR
ABS DPS-0 DPS-1 DPS-2
Class Notations
DNV GL DYNPOS(AUTS) DPS(1) DYNPOS(AUT) DPS(2) DYNPOS(AUTR)
IMO Equipment Class Not applicable IMO equipment class 1 IMO equipment class 2