P. 89

Figure 15 Functions of modern GOSPs.


            3.5.3  Controllers and Internal Components of Gas–Oil
                  Separators
            Gas–oil separators are generally equipped with the following control
            devices and internal components [4].

            Liquid Level Controller
            The liquid level controller (LLC) is used to maintain the liquid level inside
            the separator at a fixed height. In simple terms, it consists of a float that
            exists at the liquid–gas interface and sends a signal to an automatic
            diaphragm motor valve on the oil outlet. The signal causes the valve to
            open or close, thus allowing more or less liquid out of the separator to
            maintain its level inside the separator.

            Pressure Control Valve
            The pressure control valve (PCV) is an automatic backpressure valve that
            exists on the gas stream outlet. The valve is set at a prescribed pressure.