Page 84 - Petroleum and Gas Field Processing
P. 84

Figure 11  (a) Single-barrel horizontal separator; (b) horizontal separator
            schematic.



                 The following is a brief description of some separators for some
            specific applications. In addition, the features of what is known as
            ‘‘modern’’ GOSP are highlighted.

            Test Separators
            These units are used to separate and measure at the same time the well
            fluids. Potential test is one of the recognized tests for measuring the
            quantity of both oil and gas produced by the well in 24 hours period under
            steady state of operating conditions. The oil produced is measured by a
            flow meter (normally a turbine meter) at the separator’s liquid outlet
            and the cumulative oil production is measured in the receiving tanks.






 Copyright 2003 by Marcel Dekker, Inc. All Rights Reserved.
   79   80   81   82   83   84   85   86   87   88   89