Page 298 - Pipeline Rules of Thumb Handbook
P. 298

Gas—Compression    285

                                      Convert compression ratio to discharge temperature












































                      Example:
                      Given:
                        Compression ratio, r = 10
                                         = 10,000Icfm
                        Q 1
                        k                = 1.15
                        Inlet temperature T 1 = 0°F.
                      Find:
                        Discharge temperature

                      Answer:
                        T 2 = 230°F. (Approximately)




                                                     Discharge temperature