         Nomographs for estimating compressor performance*


                                                Convert SCFM to inlet CFM









































                      Example:
                      Given:
                        Standard cfm = 60,000
                        Pressure (P 1 ) = 100psia
                        Temperature (T 1 ) = 100°F.
                      Find:
                        Inlet cfm
                      Answer:
                        9,700ICFM









                                                  Inlet cubic feet per minute






         * Reprinted by permission of Gas Processors Suppliers Association.