466   Major Process Equipment Maintenance and Repair



















































                  Figure 9-12. CW352 Control Panel (courtesy Westinghouse Canada).




           designed for machines through the 60s and early 70s. They attempted to
            achieve reliability through  simplicity. In the 70s, solid state electronics
           became popular for gas turbines. Digital and digitallanalog hybrid systems
            (Figure 9-12) were developed. These systems allow much more flexibility at
            the expense of simplicity. There is a continuing debate about whether added
            complexity and redundancy provide reliability.