Page 267 - Principles of Applied Reservoir Simulation 2E
P. 267
252 Principles of Applied Reservoir Simulation
NOTE: NUMP records must be read where ... de-
notes the absolute value.
4. II, 12, Jl, J2, Kl, K2, VALKX
Omit this record ifNUMKX = 0.
11 Coordinate of first region block in I direction.
12 Coordinate of last region block in I direction.
J1 Coordinate of first region block in J direction.
J2 Coordinate of last region block in J direction.
K1 Coordinate of first region block in K direction.
K2 Coordinate of last region block in K direction.
Code Value Meaning
<0 New value of x direction permeability for region
(md).
NUMKX
>0 Multiply value of x direction permeability by
VALKX.
NOTE: | NUMKX | records must be read.
5. II, 12, Jl, J2, Kl, K2, VALKY
Omit this record ifNUMKY = 0.
11 Coordinate of first region block in I direction.
12 Coordinate of last region block in I direction.
Jl Coordinate of first region block in J direction.
J2 Coordinate of last region block in J direction.
Kl Coordinate of first region block in K direction.
K2 Coordinate of last region block in K direction.
Code Value Meaning
<0 New value ofy direction permeability for region
NUMKY
(md).