Page 177 - Process Modelling and Simulation With Finite Element Methods
P. 177
164 Process Modelling and Simulation with Finite Element Methods
Boundarv Mode
Use the Mulitphysics mode to switch to mode bulk. Select
domain 1 and enter Dirichlet BCs
Iu lv Iw
I Rzu0-U I R=vO-V 1 R=-W I
Select domain 2
Enter Neumann BCs (G=O) for all variables.
Use the Mulitphysics mode to switch to mode surface. Select
domain 1,2 and enter Neumann BCs (G=O) for all variables.
cl: Select domain 1: r=uout
c2: Select domain 1: r=vout
Apply/OK
ns: Select domain 1 : u=u1
Adv/OK
~
conv refers to the convective flux >> diffusive flux boundary condition.
Pull down the options menu and select Add/Edit constants. The AddEdit
constants dialog box appears. Assign the constants as below.
Ufeed Vfeed Du Dv Dw
1 0.4 1 1 0.001
f K ku kv kw
0.02 1 e-5 0.2 1 100
NOTE
operation
Now pull down the Subdomain menu and select Subdomain settings. Assign
Now pull down
the
U V W
r -UZ*DU -VZ*DV -Wz*Dw
F -u*Uz-ku*(U-US) -u*Vz-kv*(V-VS) -u*Wz-kw*(W-WS)
da 1 1 1
init sheetu(x) sheetu(x) sheetw(x)