Page 132 - Reciprocating Compressors Operation Maintenance
P. 132

Operation and Maintenance of Reciprocating  Compressors  119






                Stroke, Inches
                20  18  16  14  12  10




                                                     Oil Feed Rate Chart
                                                    For Comprwser CyHnden
                                                  A* Related M BOM, Stroke, Speed
                                               Example:  A  compressor  with  20* piston  and
                                                   16" stroke makes 300 revolutions per
                                                   minute
                                               Prom 20 inches, cylinder diameter, read across
                                               to the  line  representing  1«* stroke,  and then
                                               down to the  300-rpm line,  then across to line
                                               reprecenting 10 million square feel per quart of
                                               oil (this is an average rate of oil  feed-depending
                                               on circumstances, a (ester or greater rate may
                                               be  chosen).  Pram  (Ms  point  read  up  to  the
                                               "ContttBiplion" scale. The properconsumption
                                               is 0.6 quarts per 24-hour day..
                                               Caution:  If  feed  rate  i> bated  on  drops  per
                                               minute,  it  should  be  checked  by  measuring
                                               actual consumption during a given period.



























               400  450  500  600  700                  M  12  10  9  8  7
                                                            Rale, myilon sq fl/qt of oH
         FIGURE   3-5.  Oil  feed  rate chart for compressor  cylinders.  (Source:  Exxon
         Corporation,  Marketing  Technical Department,  Houston,  Texas)