PROCEDURE FOR CALCULATING THE CALIFORNIA SOLAR INCENTIVE REBATE  231
























































                 Figure 8.5  CSI Estimated Performance-Based Buydown Initiative rebate.





               ■ Outline the solar power cogeneration system’s net unobstructed platform area.
               ■ Use a rule of thumb to determine watts per square feet of a particular PV module
                                                                               2
                  intended for use. For example, a PV module area of 2.5 ft × 5 ft = 12.5 ft that pro-
                                                                            2
                  duces 158 W PTC will have an approximate power output of 14 W/ft .
                                                              2
               ■ By dividing the available PV platform area by 12.5 ft we could determine the num-
                  ber of panels required.