Page 298 - Steam Turbines Design, Applications, and Rerating
P. 298

600 #G 1800 #G 1500 #G 1500 #G 1250 #G 1250 #G  850 #G  850 #G  850 #G  600 #G  600 #G  1000* FTT 900* FTT 825* FTT 900* FTT 825* FTT 900* FTT 825* FTT 750* FTT 825* FTT 750* FTT 575* FTT  378* FS 302* FS 228* FS 326* FS 251* FS 373* FS 298* FS 223* FS 336* FS 261* FS  85* FS  5.86  6.30  6.6
                    Condensed Table of Theoretical Steam Rates (lb/kWh)
                       400 #G  750* FTT  302* FS  7.70  7.99  8.22  11.19  12.71  14.02  15.23  17.56  18.74  20.57  23.86  31.93  —  —

                       400 #G  448* FTT  0* FS  9.48  9.85  10.17  14.26  16.43  18.34  20.15  23.67  25.45  28.21  33.14  45.21  —  —


                       250 #G  500* FTT  94* FS  9.59  10.00  10.35  15.16  17.90  20.44  22.95  28.21  31.07  35.8  45.21  —  —  — “Theoretical Steam Rates Tables” by J. H. Keenan and F. G. Keyes, published in 1938

                       250 #G  406* FTT  0* FS  10.22  10.66  11.05  16.30  19.31  22.12  24.91  30.8  34.0  39.4  50.1  —  —  —

                       200 #G  500* FTT  112* FS  9.87  10.31  10.70  16.08  19.28  22.34  25.46  32.3  36.2  42.9  58.1  —  —  — Interpolate where necessary for intermediate values.


                       200 #G  388* FTT  0* FS  10.62  11.12  11.54  17.51  21.10  24.56  28.11  35.99  40.55  48.5  66.6  —  —  —

                       150 #G  500* FTT  134* FS  10.28  10.78  11.21  17.50  21.48  25.47  29.73  39.9  46.4  59.1  96.6  —  —  —


                       125 #G  500* FTT  147* FS  10.57  11.10  11.57  18.55  23.18  27.96  33.3  47.2  57.2  79.1  —  —  —  —
                    14.3                                     by ASME.
                    TABLE  Exhaust  pressure  3 in HgA  4 in HgA  5 in HgA  0 #G  10 #G  20 #G  30 #G  50 #G  60 #G  75 #G  100 #G  150 #G  250 #G  400 #G  NOTE:  SOURCE:


        274
   293   294   295   296   297   298   299   300   301   302   303