Page 238 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 238

Brockenbrough_Ch05.qxd  9/29/05  5:12 PM  Page 5.18



                                                 CRITERIA FOR BUILDING DESIGN


                   5.18  CHAPTER FIVE

                                 The nominal flexural strength M n of the members discussed in this article is the lower of two limit
                               states: yielding (plastic moment) and lateral-torsional buckling. The nominal flexural strength for
                               yielding (plastic moment) is
                                                                                                   (5.40)
                                                             M n = M p = F y Z x
                               where Z x is the plastic section modulus about the x axis.
                                 The nominal flexural strength for lateral-torsional buckling depends on the length between lat-
                               eral braces L b  as related to certain limiting lengths, L p and L r .
                                 When L b  ≤ L p , the limit state of lateral-torsional buckling does not apply.
                                 When L p  < L b ≤ L r ,
                                                                         L −  L  
                                                  M =  C M − ( M − .07 F S )  b  p   ≤  M p      (5.41)
                                                       b 
                                                                     y x 
                                                          p
                                                               p
                                                   n
                                                                        L −  L   
                                                                          r
                                                                             p
                                 When L b > L r ,
                                                                                                   (5.42)
                                                             M n = F cr S x ≤ M p
                                 The following definitions apply: The lateral buckling stress F cr is given by
                                                          C π  2 E       Jc   L  2
                                                      F =  b     1 + 0 078    b                  (5.43)
                                                                    .
                                                      cr
                                                          ( Lr / ) 2    Sh   r 
                                                                             ts
                                                           b ts
                                                                         x o
                               The limiting lengths are
                                                                       E
                                                              L = 176 r y                          (5.44)
                                                                  .
                                                               p
                                                                       F y
                                                          E    Jc            07.  F Sh  2
                                                                       +
                                                                                y
                                                    .
                                                                          .
                                                L = 195 r          1 + 1 6 76    xo              (5.45)
                                                 r     ts                   
                                                        07 F y  Sh            E   Jc 
                                                         .
                                                               x o
                               The term c in Eq. (5.45) is defined as follows:
                                 For a doubly symmetric I-shape,
                                                                 c = 1                             (5.46)
                                 For a channel,
                                                               c =  h o  I y                       (5.47)
                                                                  2  C w
                               where h o = distance between flange centroids.
                                 Conservatively, in lieu of Eq. (5.43), F cr may be taken simply as
                                                                   C π  2 E
                                                              F =   b                              (5.48)
                                                               cr
                                                                   ( Lr / )
                                                                    b ts
                               and L r may be taken as
                                                             L =π r   E                            (5.49)
                                                              r
                                                                  ts
                                                                     07 F y
                                                                      .
                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.
   233   234   235   236   237   238   239   240   241   242   243