Page 266 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 266

Brockenbrough_Ch05.qxd  9/29/05  5:12 PM  Page 5.46



                                                 CRITERIA FOR BUILDING DESIGN


                   5.46  CHAPTER FIVE

                                               TABLE 5.9 Minimum Bolt Pretension, kN*
                                               Bolt size, mm   A325M bolts    A490M bolts
                                                  M16              91            114
                                                  M20             142            179
                                                  M22             176            221
                                                  M24             205            257
                                                  M27             267            334
                                                  M30             326            408
                                                  M36             475            595
                                                  *Equal to 0.70 of minimum tensile strength of bolts, rounded off
                                               to nearest kN, as specified in ASTM specifications for A325M and
                                               A490M bolts with UNC threads.
                                                  Source: “Specification for Structural Steel Buildings,” American
                                               Institute of Steel Construction, Chicago, Ill., 2005, with permission.


                                 When A490 or A490M bolts over 1 in (25 mm) in diameter are used in slotted or oversized holes
                                              5
                               in external plies, a  / 16-in-thick (8-mm) hardened washer (conforming to ASTM F436 except for
                               thickness) should be used in lieu of the standard washer.

                   5.9.6 Holes for Bolted Connections
                               Maximum nominal sizes of holes for bolts are given in either Tables 5.10 or 5.11, but larger holes are
                               permitted in column base details, such as required for location tolerance of anchor rods. Standard
                               holes or short-slotted holes transverse to the direction of the load should generally be used, unless
                                                                                         1
                               oversized holes or slotted holes are required and approved. Finger shims up to  / 4 in (6 mm) thick
                               may be used in slip-critical connections without reducing the nominal shear strength of the fastener
                               to that specified for slotted holes.
                                 Oversized holes are permitted in any or all plies of slip-critical connections, but must not be used
                               in bearing-type connections. Hardened washers should be installed over oversized holes in an outer
                               ply when high-strength bolts are used.
                                 Short-slotted holes may be used in both slip-critical or bearing-type connections. Slots may be
                               used for any direction of loading in slip-critical connections, but should have their length normal to
                               the direction of the load in bearing-type connections. Washers should be installed over short-slotted
                               holes in an outer ply and, when high-strength bolts are used, hardened washers should be used.
                                 Long-slotted holes may be used in only one of the connected parts of either a slip-critical or
                               bearing-type connection at an individual faying surface. Long-slotted holes may be used for any


                               TABLE 5.10  Nominal Hole Dimensions, in
                                             Standard hole  Oversized hole  Short-slot       Long-slot
                                Bolt diameter  diameter     diameter     (width × length)  (width × length)

                                   1            9             5             9  11            9    1
                                    / 2          / 16          / 8          / 16 × / 16       / 16 × 1 / 4
                                   5            11            13           11  7             11   9
                                    / 8          / 16          / 16         / 16 × / 8        / 16 × 1 / 16
                                   3            13            15           13 / 16 × 1       13   7
                                    / 4          / 16          / 16                           / 16 × 1 / 8
                                   7            15            1            15   1            15   3
                                    / 8          / 16         1 / 16        / 16 × 1 / 8      / 16 × 2 / 16
                                                                                5
                                                                                              1
                                                                                                  1
                                                 1
                                                               1
                                                                            1
                                    1           1 / 16        1 / 4        1 / 16 × 1 / 16   1 / 16 × 2 / 2
                                                                                   3
                                    1             1            5         (d + / 16) × (d + / 8)  (d + / 16) × (2.5 × d)
                                                                                             1
                                   ≥1 / 8      d + / 16      d + / 16
                                 Note:  d is nominal bolt diameter, in.
                                 Source:  “Specification for Structural Steel Buildings,” American Institute of Steel Construction, Chicago, Ill., 2005,
                               with permission.
                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.