Page 453 - The Engineering Guide to LEED-New Construction Sustainable Construction for Engineers
P. 453

Notation     413

             Symbol            Chapter   Definition (typical units as applicable)
             R                 2           Defined as the area of the hardscape that has an SRI of
                                         at least 29
             R                 6           Ideal gas law constant. One value is 0.0821 L·atm/
               Ideal
                                         (mol · K)
             R                 2          Sum of the areas with high SRI excluding those areas
               mod
                                         that are shaded
             RA                6         Floor area of regularly occupied room area j
                j
             RAT               6         Total floor area of all regularly occupied room areas
             Rc                4           Refrigerant charge of system i (lb of refrigerant/ton
                i                                                                    ac
                                         of cooling capacity)
             REC               4           Renewable energy cost credit for on-site renewable
                                         energy (energy $/yr)
             REE               4         Renewable electrical energy credit for on-site renewable
                                         energy (kWh/yr)
             RH                3         Relative humidity (%)
             RRL               2           Sum of the low-slope roofed areas with an  areal
                                         weighted average SRI greater than 78
             RRS               2          Sum of the steep-slope roofed areas with an areal
                                         weighted average SRI greater than 29 (RRS)
             RW                3         Reuse water used for irrigation
             S                 2         Effective area of the hardscape that is shaded
                                                                     3
                                                                               3
             S                 10        Storage volume in a BMP (length , usually ft )
              BMP
                                                                            3
                                                                                     3
             S                 10          Storage volume in the gravel layer (length , usually ft )
              Gravel
             S                 10          Storage volume in the pervious concrete layer (length ,
                                                                                     3
              Pervious
                                                 3
                                         usually ft )
             SD                5         Standard deviation
             SHOWERS           2         Number of showers required
             SR                3          Shower water use rate for fixture type i (usually gal/
                i
                                         min or gpm)
             SRI               2         Solar reflectance index
             STRDECK           5           Total square footage of structural roof decking, interior
                      RE
                                         floor decking, and the foundation with decking or slab on
                                         grade which are intended to be reused from the existing
                                         structure, excluding any areas that are considered to be
                                         structurally unsound or hazardous materials
             STRDECK           5           Total square footage of structural roof decking, interior
                      T
                                         floor decking, and the foundation with decking or slab
                                         on grade, excluding any areas that are considered to
                                         be structurally unsound or hazardous materials
   448   449   450   451   452   453   454   455   456   457   458