Page 452 - The Engineering Guide to LEED-New Construction Sustainable Construction for Engineers
P. 452

412    App endix  A


             Symbol            Chapter   Definition (typical units as applicable)
             PBU               2         Peak building users during shift j (people per shift)
                 j
             PD                2           Previously developed: all areas that have been built
                                         upon, landscaped, or graded (this does not include
                                         areas that may have been farmed in centuries past
                                         and have returned to natural vegetation)
             PDEE              4           Proposed design electrical energy from the PDEM
                                         model (kWh/yr)
             PDEM              4         Proposed design energy model (energy $/yr)
             PDEMP             4          Proposed design energy model process load (energy
                                         $/yr)
             PDEMR             4          Proposed design energy model regulated load (energy
                                         $/yr)
             PED25LS           2           The special pedestrian areas with a minimum of 25%
                                         landscaping
             PGEBAE            4           Percent green electricity (from off-site) based on the
                                         building annual energy (BAE) model if EAc1 Option
                                         1 is not sought
             PGEPB             4           Percent green electricity (from off-site) based on the
                                         proposed building performance (PBP) model if EAc1
                                         Option 1 is sought
             PREBAEC           4           Percent renewable energy based on the building
                                         annual energy cost (Option 2)
             PREPDEM           4          Percent renewable energy based on the proposed
                                         design energy model (Option 1)
             PRR               3          Prerinse spray water use rate for fixture type i (usually
                 i
                                         gal/min or gpm)
                                                         3
                                                                        3
             Q                 10        Runoff rate (length /time, usually ft /s or cfs)
                                                                          3
             Q                 10          Miscellaneous flows into a BMP (length /time, usually
               misc
                                           3
                                         ft /s or cfs)
                                                                                    3
                                                                     3
             Q                 10          Total runoff out of a BMP (length /time, usually ft /s
               out
                                         or cfs)
             Q                 4           The gross ARI rated total cooling capacity of all HVAC
               total
                                         or refrigeration (ton )
                                                          ac
             Q                 4           The gross ARI rated cooling capacity of an individual
               uniti
                                         HVAC or refrigeration unit  i in ton . (A ton  of
                                                                          ac      ac
                                         cooling capacity is based on an older system of rating
                                         refrigeration when tons of ice were delivered for
                                         iceboxes. The tonnage given is actually in tons of ice
                                         melted in 24 h. One ton  of cooling can be directly
                                                              ac
                                         converted to 12,000 Btu/h)
                                                                                3
             Q                 10          Runoff from upslope areas into a BMP (length /time,
               up
                                                 3
                                         usually ft /s or cfs)
   447   448   449   450   451   452   453   454   455   456   457