Page 88 - The Engineering Guide to LEED-New Construction Sustainable Construction for Engineers
P. 88

LEED Sustainable Sites     69

             next to these open spaces has appropriate features such as etching to lessen these
             concerns. If there are special circumstances or considerations for any of the cases, a
             narrative must be submitted describing these circumstances. A point may be given for
             exemplary performance in the Innovation in Design category if it can be demonstrated
             that any of the three case requirements for open space are doubled. This means the
             following for each case:
                  •  For Case 1, exceeding the local zoning’s open-space requirement for the site by
                    50 percent
                  •  For Case 2, providing vegetated open-space areas adjacent to the building that
                    are equal to double the building footprint when the project has no local zoning
                    requirement
                  •  For Case 3, providing vegetated open space equal to 40 percent of the project
                    site area when no open space (zero) is required by local zoning code
                 For the exemplary performance case, each case has the following sets of equations
             which are also summarized in Table 2.5.2 along with the regular credit criteria equations.

             Case 1 Exemplary Performance  One exemplary performance point may be earned on
             most sites if

                                       OS ≥ 1.5(OSZONE/100)A                    (2.5.11)
                                                            T
             or, on urban sites where SSc2 is also earned,


                               OS + VR + PED25LS ≥ 1.5(OSZONE/100)A             (2.5.12)
                                                                   T



          Criteria for  Condition  Most Sites              Urban Sites That Also Earn SSc2
          Case 1     OSZONE in     OS ≥ 1.25(OSZONE/100)A  OS + VR + PED25LS
                                                       T
          credit point  Zoning Code                        ≥ 1.25(OSZONE/100)A T
          Case 1     OSZONE in     OS ≥ 1.5(OSZONE/100)A   OS + VR + PED25LS
                                                      T
          EP point   Zoning Code                           ≥ 1.5(OSZONE/100)A T
          Case 2     No Zoning     OS ≥ BF                 OS + VR + PED25LS ≥ BF
          credit point  Code
          Case 2     No Zoning     OS ≥ 2BF                OS + VR + PED25LS ≥ 2BF
          EP point   Code
          Case 3     OSZONE not in   OS ≥ 0.2A             OS + VR + PED25LS ≥ 0.2A
                                           T                                     T
          credit point  Zoning Code
          Case 3     OSZONE not    OS ≥ 0.4A               OS + VR + PED25LS ≥ 0.4A
                                           T                                     T
          EP point   in Zoning
                     Code
        TABLE 2.5.2  Summary of Open-Space Criteria Equations LEED 2009
   83   84   85   86   87   88   89   90   91   92   93