64                            5. Preventing Material and Assembly Problems


                         around), and tied every other wire in parallel, as the hot side, and every other wire in
                         parallel as the return side, the inductance was lower by a factor of  10. When you
                         think of it, if you take some cables that are supposed to look like 75 R, and you par-
                         allel 10 of these pairs, it should have pretty flat response, quite suitable for driving an
                         84 load. Much better than some of the monstrous huge cables, and less bulky, and
                         much cheaper, too.


           References

                       1.  Pease, Robert A., “Programmable Pulser Takes 5-nsec Steps,” EDN, May 10, 1990, p. 150.
                       2.  Kidder, Tracy, The Soul ofa New Machine, Avon Books, New York, NY, 198 1, p.  265.