Page 204 - Using ANSYS for Finite Element Analysis Dynamic, Probabilistic, Design and Heat Transfer Analysis
P. 204

Design optimization   •   191
                           be optimized for minimum weight subject to a maximum von Mises
                           stress limit of 150 MPa. You are allowed to vary the thickness t  and
                                                                             1
                           fillet radius fil. First, enter the optimizer and identify the analysis file.
                           1.  Choose menu path Main Menu> Design Opt> Analysis File>
                              Assign. The Assign Analysis File dialog box appears.
                           2.  In the Files list, click once on hexplate.lgw and then click on
                              OK.
                        3.  Identify the optimization variables
                            1.  Choose menu path Main Menu> Design Opt> Design Vari-
                               ables. The Design Variables dialog box appears.
                            2.  Click on  Add.  The  Define  a  Design  Variable  dialog  box
                               appears.
                            3.  In the list of parameter names, click on T1. Type 20.5 in the
                               MIN field and 40 in the MAX field. Click on Apply.
                            4.  In the list of parameter names, click on FIL. Type 5 in the MIN
                               field and 15 in the MAX field. Click on OK.
                            5.  Click on Close to close the Design Variables dialog box.
                            6.  Choose menu path  Main Menu> Design  Opt> State Vari-
                               ables. The State Variables dialog box appears.
                            7.  Click on Add. The Define a State Variable dialog box appears.
                            8.  In the list of parameter names, click on SMAX. Type 150 in the
                               MAX field. Click on OK.
                            9.  Click on Close to close the State Variables dialog box.
                           10.  Choose menu path Main Menu> Design Opt> Objective. The
                               Define Objective Function dialog box appears.
                           11.  In the list of parameter names, click on VTOT. Set the TOLER
                               field to 1.0. Click on OK.
                        4.  Run the optimization
                           This step involves specifying run time controls and the optimization
                           method, saving the optimization database, and executing the run.
                           1.  Choose menu path Main Menu> Design Opt> Controls. The
                              Specify Run Time Controls dialog box appears.
                           2.  Change the OPKEEP setting from “Do not save” to “Save.”
                              Click on OK.
                           3.  Specify an optimization  method. Choose menu path  Main
                              Menu> Design Opt> Method/Tool. The Specify Optimization
                              Method dialog box appears.
                           4.  Choose Subproblem. Click on OK. Click OK again.
                           5.  Save the optimization  database. Choose menu path  Main
                              Menu> Design Opt> Opt Database> Save. In the Selection
                              field, type hexplate.opt0. Click on OK.
   199   200   201   202   203   204   205   206   207   208   209