268                   Valve  Selection  Handbook



































            Figure 7-5. Capacity Correction Factor K p for  Pressure Relief Valves in Liquid Service
            that  Requires an Overpressure of 25% to Open Fully. At an Overpressure  Lower  than
            10%, There Is a Heightened Possibility  of Valve  Chatter.  (Reprinted  from  API  RP 520
            Parti, 6th Edition, March  1993, Courtesy of American  Petroleum  Institute.)










                                                   Figure 7-6. Capacity Correction
                                                   Factor  KW for  Bellows  Balanced-
                                                   Pressure Relief in  Liquid Service
                                                   that  Requires an Overpressure  of
                                                   25% to Open Fully. For Values of
                                                   KW for  Pressure Relief Valves that
                                                   in Liquid Service Open  Fully
                                                   within  10% Overpressure,  Consult
                                                   Manufacturer. (Reprinted  from
                                                   API RP 520  Part \, December
                                                   1976, Courtesy of American
                                                   Petroleum  Institute.)
   276   277   278   279   280   281   282   283   284   285   286