CAT3525_C12.qxd  1/27/2005  4:11 PM  Page 421
                       Hazardous Waste Generator Requirements                                      421


























































                                                                   FIGURE A.12.6 Hazardous waste storage area.
                                                                   Photo by Theresa M. Pichtel.


                       in order to neutralize it. This neutralized mixture of approximately pH 6.5 has been disposed on the
                       company’s property using a permitted deep-well injection system.
                          For financial reasons, the facility owner abandoned the company premises. State inspectors
                       quickly detected the presence of liquids in most of the facility tanks. The owner was required to
                       return and conduct a waste determination for all tanks. In the neutralization tank, liquids failed the
                       TCLP test for chromium. Since the contents of these tanks have consistently been deep-well-
                       injected, there was concern that high levels of chromium were also being injected
                          During an interview with an inspector, the owner stated that “We don’t know how that
                       chromium got there.”