Page 195 - Wastewater Solids Incineration Systems
P. 195

162         Wastewater Solids Incineration Systems















































        FIGURE 7.12  A dry electrostatic precipitator (courtesy of Environmental Elements Corp.).


                        Several factors influence the design and particulate removal efficiency of a dry
                    ESP, including particle size distribution, gas flow rate, uniformity of gas flow in the
                    ESP, resistivity of the fly ash, particle density, and temperature of the exhaust gas.

                    2.6.1 Performance
                    Most dry ESP installations comprise three or more fields. This allows one of the
                    fields to be bypassed while the others remain in service. On recent installations at
                    power plants, as many as five fields are used with a minimum of four in operation
                    at all times. Each field removes a greater percentage of the total inlet particulate
                    loading. Depending on resistivity of the fly ash, particle size distribution, flue gas
   190   191   192   193   194   195   196   197   198   199   200