Page 271 - Wastewater Solids Incineration Systems
P. 271

Incinerator Operations        233




             TABLE 10.2  Typical data collection spreadsheet for MHFs (deg F   °F and °F   0.5556
             (°F   32)   °C; In W.C.   in H O and in H O   0.2488   kPa; WT T/hr   wet tons per hour
                                        2          2
             and ton   0.9072   Mg; ID   induced draft; SL Comb Damper   sludge combustion air damper;
                                            3
             CF   cu ft and cu ft   0.02832   m ; gpm   0.06308   L/s; psi   6.895   kPa; Min 21   this
             incinerator is subject to a minimum pressure differential across its Venturi/impingement tray
             scrubber of 21 in water column on a daily average basis [in   25.40   mm] [this note it to
             remind operators of the pressure differential limit]; A   damper in automated mode; and
             M   damper in manual mode).


















































                                                                   (continued on next page)