Page 271 - Wastewater Solids Incineration Systems
P. 271
Incinerator Operations 233
TABLE 10.2 Typical data collection spreadsheet for MHFs (deg F °F and °F 0.5556
(°F 32) °C; In W.C. in H O and in H O 0.2488 kPa; WT T/hr wet tons per hour
2 2
and ton 0.9072 Mg; ID induced draft; SL Comb Damper sludge combustion air damper;
3
CF cu ft and cu ft 0.02832 m ; gpm 0.06308 L/s; psi 6.895 kPa; Min 21 this
incinerator is subject to a minimum pressure differential across its Venturi/impingement tray
scrubber of 21 in water column on a daily average basis [in 25.40 mm] [this note it to
remind operators of the pressure differential limit]; A damper in automated mode; and
M damper in manual mode).
(continued on next page)