12-20   WATER AND WASTEWATER ENGINEERING

                                  12-3.   Estimate the area of membrane required for Bar Nunn’s new membrane filtration
                                     plant. The manufacturer of one of the membranes they have selected for testing has
                                     provided the following data:

                                            Maximum TMP     103 kPa
                                                               1
                                                       10
                                          R    m        3.1     10    cm
                                     Based on their pilot tests, Bar Nunn has selected the following operating parameters:
                                           Operating TMP     75% of maximum TMP
                                          Temperature     20 	 C
                                                        3
                                          Q    max        181.7 m  /d
                                  12-4.   Bar Nunn has investigated an alternate manufacturer to the one identified in
                                     Problem 12-3. The alternate manufacturer offers a vacuum operated system that
                                     uses a maximum TMP of    55 kPa. With the exception of the TMP, the operating
                                     conditions are the same as those given in Problem 12-3. The capital cost of mem-
                                                    2
                                     brane is $1,100/m   for both membranes, but the operating costs are less for the
                                     vacuum system because of the lower TMP. If the vacuum system operating costs
                                     are $16,500 per year and those for the pressure system are $33,000 per year and
                                     Bar Nunn uses 6.00% interest and a 10-year membrane life to evaluate alternatives,
                                     which system should be chosen based on these costs alone?
                                                                         3
                                                                                                          3
                                  12-5.   Yeehaw’s winter water demand is 10,400 m  /d, and its summer demand is 15,600 m  /d.
                                     If the membrane filtration system is designed for the winter demand, can the system
                                     meet the summer demand with the same area of membrane? The proposed winter and
                                     summer design conditions are:
                                          Maximum TMP     152 kPa
                                          Operating TMP     75% of maximum TMP
                                                             1
                                                        12
                                          R    m        2.94     10    m
                                          Winter water temperature     4 	 C
                                          Summer water temperature     20 	 C
                                                                           3
                                  12-6.   Snowshoe’s winter water demand is 7,600 m  /d, and its summer demand is
                                             3
                                     10,200 m  /d. If the membrane filtration system is designed for the winter demand,
                                     can the system meet the summer demand with the same area of membrane? The pro-
                                     posed winter and summer design conditions are:
                                          Maximum TMP     200 kPa
                                          Operating TMP     75% of maximum TMP
                                                            1
                                                       12
                                          R    m        3.2     10    m
                                            Winter water temperature     1 	 C
                                           Summer water temperature     15 	 C
                                  12-7.   A membrane manufacturer’s data sheet reports the following:
                                                                       2
                                          Initial specific flux     1.24 L/h · m   · kPa at 20 	 C
                                                          2
                                          Flux     33 L/h · m
                                                       12
                                                            1
                                          R    m        2.9     10    m
                                     What is the TMP for these conditions?