Page 108 - Advanced Design Examples of Seismic Retrofit of Structures
P. 108

(A)                                (B)












                   (C)                              (D)
















                (E)                         (F)
















                                (G)
            FIG. 2.50 The necessary steps in shotcreting of walls. (A) Removing the walls finishing.
            (B) Cleaning the walls surface by water jet. (C) Drilling the walls for insertion of shotcrete connec-
            tion bars. (D) Installation of reinforcement grid. (E) Spraying concrete. (F) Concrete curing.
            (G) Applying walls finishing and painting. (Permission from DRES.)