154   Advanced Design Examples of Seismic Retrofit of Structures



                  TABLE 3.9 Assumed Material Properties

                                                           Value, MPa
                  Parameter                             f ex   f cL
                  Compressive strength of concrete in the shear wall  22.5  14.5
                  of the northern building part
                  Compressive strength of concrete in the shear wall  24.5  17.5
                  of the southern building part
                  Compressive strength of concrete in the columns  19.7  13.5
                  Compressive strength of concrete in the  21.0  18.0
                  diaphragms
                  Tensile strength of unribbed bars     300
                  Tensile strength of ribbed bars       370



            3.5.1.1 Loads
            The considered load cases are dead, live, and seismic, which are based on the
            Iranian National Building Code; Part 6: Loading [7].

            Dead and Live Loads
            The dead loads of the peripheral walls are defined in the model based on the
            details from the field studies. The assumed dead and live loads are presented
            in Table 3.10.


                    TABLE 3.10 Dead and Live Loads
                    Dead Loads
                    Peripheral walls with 20cm thickness  660kg/m
                    Parapet walls                    123kg/m
                    Stories and roof                 240kg/m 2
                    Live loads
                    Offices                          250kg/m 2
                    Partition walls                  100kg/m 2
                    Roof                             150kg/m 2
                    Stairs                           500kg/m 2
                    Equipment rooms                  400kg/m 2