Page 158 - Advanced Design Examples of Seismic Retrofit of Structures
P. 158

150   Advanced Design Examples of Seismic Retrofit of Structures























            FIG. 3.19, CONT’D (B) Zoomed view.



              TABLE 3.8 AHP Scoring Table of the Retrofit Strategies
                                                         1st        2nd
              No.    Item                        Score   Strategy   Strategy
              1      Construction costs           20     20         14
              2      Construction time            15     15         12
              3      Parallel progress in architectural,  17  6      5
                     mechanical and electrical
                     equipment
              4      Flexibility for possible changes in  6  5       4
                     architecture
              5      Feasibility and straightforwardness  6  5       3
              6      Unnecessary full-time supervision  6  5         4
              7      Possibility of further retrofitting of  7  5    4
                     members (if necessary)
              8      Unnecessary added foundation  10     7          6
              9      Environmentally-friendly      8      6          4
              10     Unnecessary maintenance costs  8     8          4
              11     No conflict with the access routes,  7  6       3
                     pathway, etc.
              Overall score                      100     88         63